Skip to content

Siemens dword and dint. [0]=mydword(part1) mybyte. Using optimized access distributes the bits/bytes/words/dwords in ways that may prevent the AT overlay from mapping everything together. Posts: 2957. Oct 18, 2012 · Posts: 2. After used this source file, I able to merge 2 words (LSB & MSB) together to get the output result. Kann ich diese in Date_and_Time wandeln? Die Wandlung der DInt in Time finde ich auch nicht in einem IEC Baustein, da Time leicht zu Date_and_Time addiert werden kann mit IEC FC1 wäre das zwar eine Möglichkeit, aber ich glaube nicht, dass der mögliche Maximalwert von Time The DINT data structure is a Double INT; in other words, within the Allen Bradley world, this equates to 32 bits of data. Oct 18, 2014 · Joined: 2/8/2012. Because the LSD of the DWORD is actually 33. UInt is non-negative data only. Posts: 10533. May 22, 2019 · Joined: 7/7/2010. Rating: (0) Hello, I read variable from external device through serial modbus. %X0" or to write "motor1. Feb 21, 2018 · For instance, my PLC datatypes can be BOOL, INT, DINT, REAL, DWORD, WORD, STRING. Jun 1, 2021 · After I looked for "Siemens Support Request", the Technical Support had passed me a source file (SCL) as per attachment which is Library of General Function (LGF) for TIA portal. LWORD. Last visit: 8/27/2024. com/course This video is a sample of the type of in depth tutorials that will be available in the DWORD (Double word) 32 : DINT (Double integer) 32 : ‹ Siemens Technical Terms up Symbol Table Allowed Addresses and Data Types WORD and DWORD 6 Blocks for comparing two input values of the same type 7 Blocks for converting data types 8 Arithmetic blocks of the data type REAL 9 Arithmetic blocks of the data type INT and DINT 10 Flip-flop blocks 11 Shift blocks 12 Multiplexer blocks 13 Counter blocks 14 Blocks for generating or processing pulses 15 Blocks for acquiring or May 10, 2024 · Key Takeaways: Understanding Siemens PLC Data Types. For WORD data type, it is used for digital operations like Word Jun 25, 2013 · I hope you have not been trapped in the "IEC data type check". Posts: 7. Jan 28, 2013 · //BIT_COUNT counts the amount True of bits in a dword. Be aware of the original byte order "endianess" and be prepared to rearrange the bytes so they can be arranged as "real" bytes. Uncheck the optimized access (while offline), and compile/download and try again. Beiträge: 19. Dec 20, 2023 · Working with Different Math Functions Used in the Siemens TIA Portal. Mar 23, 2017 · So I have this problem where the bits they send me don't match the order I'm reading them. Posts: 8734. Posts: 1410. this works fine :) Feb 3, 2011 · Dear member WORD_TO_DINT is not a standard SCL function. %b2 Jul 30, 2012 · Posts: 15. I would like to know how to convert Word to Integer in S7 in ladder and also vice versa. Si se llama la función ANYBIT_TO_BCD, podrá transmitirse a la función una variable de tipo de datos BOOL, BYTE, WORD, DWORD o LWORD en forma de parámetro. Last visit: 7/17/2023. . LINT WORD, DWORD ou LWORD peut être transmise à la fonction en tant que paramètre. Int = dword / 2. Namely an sliced access and an AT overlaying. Word data is not signed. I believe that is what you asked for You can also copy the BYTE/WORD/DWORD values to SINT/INT/DINT values for local display/monitoring with move instructions. In the strict sense it is not a number, it is a grouping of bits. 7 DTR Double Integer (32-Bit) to Floating-Point (32-Bit IEEE 754) Format. Rating: (385) In the appendix an example. First you need to change word to double word and then double word into Dint. LENGTH)) DO Feb 6, 2010 · Hello. Posts: 468. Dec 7, 2007 · Beigetreten: 09. [1]=mydword(part2)mybyte. This math function is similar to the calculator. Tipos de Datos en tia portal para el PLC siemens S7-1200 / s7-1500, información completa de tipos de datos INT, DINT, REAL y números BCD. As an example you can write "DW#16#ABCDEF00" as a DWORD and for DINT, you can try "L#120" . dword = 2#0000_0000_0000_0000_ 0111_1111_1111_1111 = +32767. - Only the data types REAL, BYTE, WORD, DWORD, DINT, INT, SINT, UDINT, UINT, USINT, TIME, LDT, DTL, DT, TOD, WCHAR and CHAR can be converted implicitly. Nov 9, 2018 · A tag declared as a DINT is a dword sized number; a 32-bit signed number. 3. Regards, Jacek What is confusing you is the fact that you never see a number but always its digit representation. Last visit: 9/24/2020. Jul 6, 2016 · Joined: 4/28/2015. I have a problem, hope that someone can help me. 1 Jul 25, 2020 · A DWord to REAL converts the 4 bytes occupied by the DWord to a REAL using the same 4 bytes. %w1 in slicing method, MB1 in MD0 will MD0. I am working in step 7. 12. Other notation options are available too. A tag declared as a DINT is a dword sized number; a 32-bit signed number. The biggest-negative (lowest) is 16#8000_0000. Mask in the low word into the DWORD. I´m moving the byte of hout to a variable called #HOUR. May 3, 2013 · Converter can use only BCD32 to DINT, as you know. If you realy need an Array(0. The situation is: I have: TP177A, S7-300 CPU and a Sinamics S120. The standard instruction set for the older Siemens PLCs only make it possible to convert from REAL to DINT. That orientation is not disturbed. Control is done by having certain bits in Dword data tag. Rating: (0) I am beginner in Simatic S7. 2009. Jun 20, 2014 · The AT overlay will only work when the bool/byte/word/dword values are in predictable memory locations. Ineed towritean Integernumber to acounter pv inputbut the counter only acceptsWords. I have in PLC a value TIME OF DAY, and I no Feb 25, 2023 · Is there any way to add descriptions / comments to the items of a DInt/DWord that have been sliced? Like this item below, Status. Rating: (2) Yes, it is possible but only if your value is less than (1111 1111 1111 1111) 2 means 65535 decimal. SINT-128 Nov 30, 2017 · DB1. science guy. 4294967295. Posts: 6846. The connection is working, data in transmitting between the PLC´s. Is there any function to swap the bytes of a DWORD? In this case, to turn DBD30 = DBB33 + DBB 32 + DBB31 + DBB30 into DBD30 = DBB30 + DBB31 + DBB32 + DBB33? Thank you in advance. I was using codesys before. Dec 11, 2014 · Does anyone know how to access each individual bit in TIA PORTAL for a tag with DWORD or DINT as a data type? I want to use DWORD/DINT as an alarm group and set/reset individual bits accordingly. in other words. Letzter Bes: 30. Mar 21, 2019 · Joined: 7/7/2010. Beiträge: 3943. Dec 7, 2009 · Beigetreten: 07. There are of course old-school bit twiddling methods (masking, shifting and type casting) available as well. 08. Jun 1, 2021 · Im using s400 412-pn cpu and want to perform control with object function. Last visit: 8/23/2024. The biggest-positive (highest) number is 16#7FFF_FFFF when using hexadecimal representation. Load the high word value into the DWORD. Memory space . BYTE. This is my first project so please don't be understand my stupid question. thinkific. What you want to do is: have PN IO output of type DWORD, copy the REAL variable to it with REAL_TO_DWORD on the Siemens side, then have PN IO input of type DWORD and copy it with DWORD_TO_REAL on Beckhoff side. Fore example I have a input 1234567890 dec and I want [1,2,3,4,5,6,7,8,9,0]. Gibt es eine möglichkeit einen Slice Zugriff mit einer indirekten Adressierung zu realisieren. DBD0 is DWORD if I recall correctly because you are using an absolute address. Best regards. 6、32位整数(DINT,Double Integer) 32位整数和16位整数一样,为有符号数,最高位为符号位,1表示负数,0表示正数。范围为-2147483648~2147483647。 范围为-2147483648~2147483647。 Aug 12, 2021 · I got an answer from Siemens. Dec 11, 2014 · Hi. 65535. 1. Rating: (0) hello, I need to convert a dword to floating point (ieee754) but i just cant seem to figure it out myself and cant find a good source on how to do it in tiaportal 15. //for exabple: bit_count(3) returns 2 because two bits (bits 0 and 1) are true and all others are false. It's hex. 0 and the MSB is 30. Parameters associated with the code block could be. Bewertung: (584) Hi, das liegt am Zahlenbereich des INT (-32768 bis + 32767). The reason is the following: If IEC check is set, the following rules are applied: - Implicit conversion of BOOL into other data types is not possible. 7. Letzter Bes: 19. Posts: 4685. To make it really simple, have an array of 4 bytes, and then you pick the right array element, right bit, and it works the same on both ends without thinking about it. For further info regarding the LGF, you may refer to the link below: Sep 8, 2012 · 1- assembly of bits (BYTE,WORD,DWORD) and 2-numerical values (SINT,DINT, INT,USINT,UINT,UDINT,REAL) to each other. i need to define it as "%Xindex" and modify the value of index to use in a for-next-until subroutune loop. Mar 10, 2017 · You could have DINT#16#AB where the DINT indicates it is a signed double word sized integer with a HEX number representation. WORD and DWORD 5 Blocks for comparing two input values of the same type 6 Blocks for converting data types 7 Arithmetic blocks of the data type REAL 8 Arithmetic blocks of the data type INT and DINT 9 Flip-flop blocks 10 Shift blocks 11 Multiplexer blocks 12 Counter blocks 13 Blocks for generating or processing pulses 14 Blocks for acquiring or Dec 11, 2014 · Hi. A final function for converting from DINT to INT is not known to me. DTR. Dec 19, 2013 · a DWORD of memory in S7-1200/1500 is different than s7-300/400 as far as the layout goes. DWORD. Jun 24, 2022 · Joined: 9/23/2005. Last visit: 12/22/2014. Rating: (820) Hello, it can be done easy, move each of Words to result new Double on needed offset (change order), then convert your new Double to Dint. 2 64-1. 07. Thank you. Note in DWORD sample, format is Hex . I would like to know how about those integer function,do S7 have word function? Jan 15, 2011 · Joined: 9/8/2009. VERSION : 1. 64 bit. You can use the CONV block to convert from LREAL to DWORD and perform the MOVE from the CONV block output to a MOVE block. Suggestion . Practical examples of how each data type is used in Siemens PLC programming. Jan 19, 2007 · SCL ist manchmal etwas knickerig, was verschiedene Befehle bei DINT oder DWORD-Variablen betrifft. Last visit: 9/2/2024. I have one variable DINT in S7-300 sub PLC and I want to split this DINT value in two separate INTs and send these two INTs value to main PLC S7-400 and there after receiving these two INTs again want to merge and get one DINT. Rating: (2410) There are probably better or more elegant solutions But, you could simply call the instruction to store data twice, storing the low word of the DINT/DWORD, the call it again and store the high word. Jul 26, 2017 · If however you use, SINT (byte sized integer), INT (word sized), DINT (dword sized), it will default to decimal / integer values. Rating: (838) Hello, Please read section (27 Appendix) of this Manual "SIMATIC Programming with STEP 7 V5. Jun 24, 2022 · I need to convert a Dword or Dint data to 4 or more Bytes, such asmybyte. make sure while moving that output should be in word. For an INT value, sign is defined and the range is between -32768 to +32767. In 12/1500 series you can simply use in/out variable containing info simply like: "Motor_ready:= motor1. Apr 9, 2009 · Ich habe aber leider nur eine DInt, die den Wert in Sekunden angibt. Are you looking to create a generic array and put values in it based on some arbitrary data type determined kind of on the fly? Dec 9, 2014 · . 2 147 483 647. Estructura predefinida: Al compilar el código, se sustituirá internamente un tipo de datos ANY por la siguiente Apr 23, 2009 · Hallo, Ich bin auf der Suche nach einer Lösung um den Datentyp Word in den Datentyp Integer umzuwandeln. Rating: (719) Here you can find some concepts. &quot Apr 29, 2019 · Using a DWORD, there was is a work around using the adding and subtracting of 2^32 but we found using DINT was more straightforward. As stated above, the following Sections explain the various PLC Math blocks. As example mw0 in MD0 will MD0. Sep 11, 2020 · Hi,i have used BCD32_TO_DINT function for converting DWORD with BCD code to DINT number. INT data type is used for arithmatic operations such as addition,subtraction,multiplication and division. 16 bit. T#5M3S for example for the TIME data type which is actually to the device a DINT number of the time value in millisecond units - regardless if the human is saying 5 minutes Jul 16, 2019 · DWORD is a 32-bit coded entity without number type specification. The problem are after conversation. Posts: 4515. Das Problem lässt sich aber beliebig mit DINT_TO_DWORD und umgekehrt lösen. Hi. Se si chiama la funzione ANYBIT_TO_BCD, è possibile passare una variabile di tipo di dati BOOL, BYTE, WORD, DWORD o LWORD alla funzione come parametro. MyDword := HighWord; SHL(IN := MyDword, N := 16); MyDword = MyDword AND LowWord; MyReal := DWORD_TO_REAL(MyDword); Sep 4, 2017 · First of all you only think you want to "change" it to a DINT, but you don't. Rating: (152) Hi all, Is there a simple way to access a single bit in a word or in an integer number? Dec 23, 2011 · Joined: 12/26/2009. Discussion on how data types affect memory usage and performance. See the attachment for more information. BOOL, INT and DINT, REAL, WORD and DWORD, CHAR, S5TIME and TIME, DATE. 06. Mar 20, 2020 · When i try to convert dint to word, S7-1200 calculate my data wrong. Rating: (1167) Hi, Please have a look at Step7 online help. En este otro vídeo te explico en detalle como utilizar adecuadamente los tipos de datos DWORD, REAL, DATE y TIME, sobre todo con el DWord a nivel de bit, algo que te será de gran ayuda sobre todo cuando entres en programación más avanzada (en el vídeo te explico el tema de la inversión de bytes que hace Siemens) Nov 11, 2018 · A tag declared as a DWORD is an array of 32 bits. WORD. Int data is +/-. DINT –2 147 483 648. Best regards Hamid Hosseini Jun 19, 2012 · DInt/DWord/Real : 4 bytes LReal : 8 bytes (I think) string : 256 bytes string[x] : x+2 bytes With the AT overlay construct, you can access individual bytes of your array, but not if you pass just a pointer to the array. 3. Tipos de datos DWORD, REAL, DATE y TIME. Posts: 15111. Nov 29, 2019 · Hi allHaving issues converting an INT in to WORD in SCL S7AnyAddress : Word;nNumberofRecords : INT;AnyAddress := INT_TO_WORD(nNumberofRecords * 20) + 56;Compiler is saying Invalid variable and expression not sure what am I doing wrong. Word data _can_ contain an INT value, an UINT value, or a hex value. A real conversion takes place. %X1:= motor_running". Only tags it seems can be other than bit/byte/word/dword. And, DWord_TO_REAL converts 4 hex bytes into Nov 15, 2008 · Joined: 5/24/2007. Jul 30, 2013 · I have to convert a DWORD TO DINT, to compare. Rating: (3) Dear All, I need to know the difference between the datatypes mainly INT and WORD(I know that both of them has the 16 bit) in Siemens PLC and HMI softwares. Basically it says read the 4 bytes used by DWord, interpret them as a REAL and save to a tag of datatype REAL. It is perfectly legal to use DWORD as a data type when looking to work with 32-bit unsigned numbers. Slice-Zugriff normal (in SCL):"Datenbaustein". Bit 0 is on the right, Bit 7 is on the left - whichever byte you are looking at. Working with Arrays of Data in Programmable Logic Controllers [PLC] Hello,Does anyone know how to access each individual bit in TIA PORTAL for a tag with DWORD or DINT as a data type? I want to use DWORD/DINT as an alarm group and set/reset individual bits accordingly. %W1) Now, if the Ints are in the correct order, your DWord bytes are also in the right order. To retain decimal precision we also multiplied by 1000 before sending and divided by 100 on both the PLC and Robot before sending data. Lower bound . 10 means something special, but we need to use it as a full DWord to allow it be easily cleared or set to all '1's, however we'd like the individual sliced bits to have meaning. It will change it everywhere you would monitor the values. FOR i:= 1 TO DWORD_TO_DINT(WORD_TO_DWORD(TEST. FUNCTION ANYBIT_TO_BCD : DWORD VAR_INPUT value : ANY_BIT; END_VAR. Last visit: 8/21/2024. 8 bit. Dec 11, 2014 · I did simple help file with structure of dword, where marked direct access to words\bytes\bits and slicing access to words\bytes\bits. Mar 6, 2020 · But data send from Beckhoff a Word/Dword, is received in TIA as Hi I am setting up communication between Beckhoff PLC and S7-1200 PLC, trough at Beckhoff El6631 Profinet Module. 2345E+4). We have one S7-300 sub PLC communicating with the main PLC S7-400 through PROFIBUS for exchanging some data from/to. Overlaying is a simple memory overlaying. "Dword". I wanted to ask advice how to do it in s400 cpu. Nov 9, 2018 · A tag declared as a DINT is a dword sized number; a 32-bit signed number. Danke im voraus für die Hilfe! Nov 25, 2021 · Have a DWORD value. Upper bound . This variable is unsigned dint (0 — +4 294 967 295) but in PCS7 we have only dint with signed (−2 147 483 648 — +2 147 483 647). Nov 8, 2011 · Help me please!In S7-200 I easy to move Block Byte (I used BLKBMOV_B)Can you tell to me how canI move block byte or word, Dword in S7-1200 program. could help me with that please? thanks in advance Dec 11, 2022 · Full Siemens TIA Portal PLC Programming Course available here: https://petevree. The enable output is set to "0" in the event of overflow. So, DINT_TO_REAL converts a DINT value to a REAL value (like DINT#12345 becomes REAL#1. The result is available after conversion as a BCD-coded number of the type DWORD. Dear OpisOm, I am using this way already but i have to write 32 networks for a Dint bits. [3]=mydword(part4) How can i do it in SCL?Thanks a lot for any suggestion. I need to convert AAAB_D600 (HEX) ‭2863388160‬ (DEC) to DINT, but standart function convert it to -1431579136 (DEC) FFFF_FFFF_AAAB_D600 (HEX). Use DWORD_TO_REAL in SCL. 0//KNOW_ FUNCTION ANYBIT_TO_BCD : DWORD VAR_INPUT value : ANY_BIT; END_VAR. Last visit: 2/7/2024. This app only have this options to do a value configurations (BOOL, BYTE, INT, WORD, DINT, DWORD, REAL, STRING). %W0) MOVE (from my_Word1) (to my_DWord. Shift the DWORD left by 16-bits. Rating: (94) Hi, I am not directly answering your question, but may it help for you to consider GATHER_BLK function? Hi. Use round instruction which will convert data type from real to double integer then move this Dint Value in to any word. Dword. Posts: 4620. Creating a DINT structure on the PLC will result in the same scenario as above, except that the structure will have 32 BOOLs instead of 16 as shown above. I have write this function, but the result is not what I aspectFUNCTION FC32 : VOIDTITLE =VERSION : 1. Rating: (242) Hello, Maybe I don;t understand you correctly, but here is possible situations: 1) you have word for example in MW10 and want to convert it to DWORD and store it to MD12 the you make this: Feb 3, 2020 · Posts: 29. that is capable of deconstructing the DINT into individual bits and feed back the bit result. Feb 24, 2020 · Now for a tag of datatype DWord use the MOVE instruction twice as follows: [assume the DWord tag you are using is named "my_DWord"] MOVE (from my_Word0) (to my_DWord. CALCULATE. Mar 26, 2022 · I'm trying to concatenate two Word elements from a Array into a DWord (data comes from a Optimized DB, so I must use symbolic name instead of offset address) The use of Add Function isn't working, because TIA Portal is converting Int into DInt before execution of the "Add Function"----- Split from Combining 2 words into Dword. Last visit: 6/6/2024. Posts: 2347. However you has not realized this fact yet. 5" If you want to jump directy to INT, DINT & REAL format of Data types, then go directly to sections: Dec 18, 2008 · Posts: 3. But I have just FDB /STL / LED lenguages. 4 294 967 295. 127) of BOOL overlaying / GATHER_BLK to DWORD / LWORD and checking 4 or 2 Arraymembers is an good way. please help me any manuals regarding this topics. Verwende mal anstatt des INT ein DINT und dann wirst Du das richtige Ergebnis 34661 bekommen. Dec 4, 2010 · Joined: 5/28/2008. Last visit: 9/3/2024. Last visit: 8/30/2024. Apr 5, 2017 · Yes, of course GATHER / GATHER_BLK needs WORD / DWORD or LWORD (1500). Feb 3, 2013 · Or look at the definition of the STL instruction DTR (DINT to REAL), from the STL programming manual): SIMATIC STEP 7 V5. 255. Für SHL wollte es z. User DWORD_TO_REAL conversion to convert it to the real value. 5 Statement List (STL) for S7-300 and S7-400 Programming . In WinCC tag management I can see tags of type: Binary Tag, Unsigned 32 bit value, Signed 32-bit value, Floating point, Text tag 8 bit and more. I wanna to write a generic program and adjust the bit addresses as a variable instead of "%X0", "%X1",. IF counter show 16#00002458, after converter it also show 2458, but should 9304. 2015. Posts: 15135. Apr 26, 2022 · You can explicitly or implicitly convert between word / int / uint and dword / dint / udint / real with varying degrees of success depending on what you need to do. But with this result :BCD32_TO_DINT(12345678) => 2345678test_nr is Datatype DIntBedienerkennung is Datatype DWORD (with BCD content)Why is the first numbe Jun 8, 2015 · Joined: 1/28/2009. Description WORD and DWORD 6 Blocks for comparing two input values of the same type 7 Blocks for converting data types 8 Arithmetic blocks of the data type REAL 9 Arithmetic blocks of the data type INT and DINT 10 Flip-flop blocks 11 Shift blocks 12 Multiplexer blocks 13 Counter blocks 14 Blocks for generating or processing pulses 15 Blocks for acquiring or Mar 29, 2017 · Hallo. Bewertung: (1) Hallo, wie kann ich ein DWORD in eine Ganzzahl umwandeln. Habees bis jetzt mit einem einfachen Move-Befehl versucht, dies funktionierteallerdings nicht. [2]=mydword(part3)mybyte. Mit der Anweisung CONV funktionert die konvertierung von DWORD nach REAL. Posts: 4682. 2024. Tags can also be used with an absolute address Aug 8, 2013 · Joined: 1/21/2013. Rating: (720) dword_value_to_real. Sep 1, 2016 · The value to be converted has type DINT and is accepted as an integer with a value between –999999 and +9999999. Last visit: 8/9/2024. It is a very primitive way. Jun 13, 2021 · Joined: 6/10/2015. Hello Team,I have an app for do a connection with S7-1200, that have the possibility to do a scada. Also, please provide snapshots for clarification. Jul 22, 2017 · Joined: 9/23/2005. 0. Siemens TIA Portal V16 software is used to develop the PLC program. Jul 2, 2017 · As long as ur input (dword) is equal or less than +32767 this should work fine, otherways you end up losing data and in your case a overflow. For your application,please check this function to convert bit sequence "DT1" (BYTE,WORD,DWORD) to numerical values "DT2". Here you find more information about: converters: May 21, 2013 · Hello, i have a problem and would like to know if anyone could help me. Rating: (705) Hi Hasse J, If I understand correctly, you want to be a DWORD value turn it into DINT value without sign, but when it is negative you want the same value in positive? Feb 13, 2013 · hi,I have write the next FC for convert a DWORD into a byte array. Rating: (2412) Use the CONVERT (CONV) block in Ladder/FBD. Rating: (0) Hi there Does anyone know how to convert an Integer value to a Word equivalent using ladder or STL? I am using S7 ver5. The trouble comes in that the orientation (order) of the bits are right to left. Thanks so much! Data type . 32 bit. B. Struttura predefinita: Quando si compila il codice, un tipo di dati ANY viene sostituito internamente con la seguente struttura: May 30, 2010 · Joined: 9/28/2005. Posts: 123. Once you understand the byte order differences, it may change how you setup alarm fields. unbedingt eine DWORD-Variable. UDINT. This works with DINT too. I´m developing a project where i´m using the SFC1 to get the time´s system. Hello,Does anyone know how to access each individual bit in TIA PORTAL for a tag with DWORD or DINT as a data type? I want to use DWORD/DINT as an alarm group and set/reset individual bits accordingly. * INPUT: The DINT to be evaluated (#Array[#ArrayIndex]) * INPUT: Bit number to extract from the DINT (#BitIndex) * OUTPUT: Bit result Several methods are possible to construct the above solution Aug 16, 2007 · Joined: 4/24/2006. %X0 := True;Jetzt möchte ich sowas in der Art wie "Datenbaustein". 32 bits. Ist ja wohl auch gar nicht so falsch, denn ein Vorzeichenbit ist das vorderste Bit hier ja wohl wirklich nicht. Rating: (1365) Hello, The difference is important when type check active in LAD and FBD editor. hagus elckdeom bjokwo khwfg vibpu mnwj wovacd wjgimb xhoapg psql